Horizontal Slurry Pumps
Horizontal Slurry Pumps 1. The slurry pump has been injected with a proper amount of oil before leaving the factory to lubricate the mechanical seal. The oil should be checked once a year. If you find water in the oil, you should drain it, replace the oil, replace the gasket, and tighten the screw plug. After three weeks, it must be checked again. If the oil becomes emulsion again, the mechanical seal should be checked. 2. When the slurry pump is not used for a long time, it should be cleaned and lifted and placed in a ventilated and dry place, taking care to prevent freezing. If placed in water, run for at least 30 minutes every 15 days (not dry grinding) to check its function and adaptability. 3. The cable shall be inspected at least once a year. If it is damaged, please replace it. 4. Check the motor insulation and fastening screws at least once a year. If the insulation of the motor drops, please contact the after-sales service department. If the fastening screws are loose, p...